1. Access Requirements

  1. 1

    Access and use are limited to individuals who have completed the Department of Research and Experiment application process, completed radiation worker training, and received a thermoluminescent dosimeter (TLD badge) as personal radiation protection equipment.

  2. 2

    Researchers must complete the legally required initial safety training (20 hours) and annual refresher training (6 hours). Facility use is restricted if training requirements are not met.

  3. 3

    Radiation workers must undergo an annual medical examination.

2. RI Purchase

  1. 1

    Radioisotopes must be purchased through the Radiation Safety Management Office (+82-2-2072-1607). Unauthorized individual purchases are strictly prohibited.

  2. 2

    All radioisotopes must be stored at the authorized location (the RI Storage Room in CMI B2309) in shielded storage containers.

  3. 3

    Sealed containers must always be checked for contamination. Any contamination must be reported immediately so that appropriate action can be taken.

RI Purchase Procedure

RI Purchase Procedure Flowchart The researcher submits an RI Purchase Request Form to the B2309 RI Office by Tuesday (1). B2309 submits the purchase request to the Radiation Safety Management Office (2), which requests authorization from the Radiation Safety Officer (3) and receives approval (4). The office then places the order with the supplier (5), verifies the weekly Tuesday delivery (6), transfers the RI to B2309 (7), and stores and releases it to the researcher (8) for RI experiments. Researcher RI Experiment B2309 RI Office Radiation Safety Office Radiation Safety Officer Supplier 1 8 RI Purchase Request Form Complete and Submit (By Tuesday) Verify RI and Store 2 7 Purchase Request Verify and Transfer RI 3 4 RI Purchase Approval Request Approval 5 6 RI Purchase Order (Send Request Form) RI Delivery and Verification (Every Tuesday)

3. Disposal Procedure

  1. 1

    All waste must be reported to the staff member and disposed of in the staff member’s presence according to the established procedure.

  2. 2

    Waste segregation: All waste must be separated by radionuclide and classified as liquid or solid waste.

    • · Liquid waste - Separate aqueous and organic-solvent waste
    • · Solid waste - Separate combustible and noncombustible waste
    • · Caution: Before disposing of liquid waste, ensure that the collection container will not overflow and pour slowly.
  3. 3

    Tissues, poly gloves, Safer mats, and other materials used in radioisotope experiments must be treated as radioactively contaminated and placed in the designated waste containers in the facility.

  4. 4

    Measurement samples must be removed from the instrument immediately after measurement and disposed of as radioactive waste.

  5. 5

    After disposal, record the disposal details in the waste log.

Radioactive Waste Disposal Procedure

Radioactive Waste Disposal Procedure Flowchart Radioactive waste generated by radioisotope experiments is segregated into solid waste (tips and tubes, plates, paper and vinyl, rubber items, and solid-waste bottles) and liquid waste (aqueous and organic-solvent waste). It is disposed of in the presence of a staff member and recorded in the waste log. Disposal methods are classified as on-site or contracted disposal by item. Radioisotope Experiment Radioactive Waste Generated Solid Tip, Tube Plate Paper and Vinyl Rubber Items Solid-Waste Bottles Liquid Aqueous Organic Solvent On-site Disposal Contract Disposal Segregation With Staff Present Dispose Waste Log Complete

4. Requirements for Radiation Workers

The Radioisotope Core Facility operates in accordance with hospital safety management guidelines, applicable nuclear laws, and radiation safety regulations.

  1. 1

    All radioisotopes must be used only within authorized facilities.

  2. 2

    Comply with all Radioisotope Core Facility rules.

  3. 3

    Wear required protective equipment, including a laboratory coat, protective gloves, and dedicated footwear. Eating, drinking, and smoking are strictly prohibited in the laboratory.

  4. 4

    Before and after each experiment, measure the workbench and related facilities for contamination and record the readings and your signature in the contamination monitoring log.

  5. 5

    Radioactive waste must be strictly segregated by radionuclide and physical form (liquid or solid) and disposed of according to the established procedure in the presence of a staff member.

  6. 6

    Any contamination incident, regardless of scale, must be reported to the staff member immediately. Untrained individuals must not attempt decontamination.

  7. 7

    Treat even minor exposure as hazardous. If contamination occurs, promptly contact the staff member and follow the required response measures.

  8. 8

    Remember that accidents can result from complacency and negligence. Always conduct a preliminary trial before beginning an experiment and keep the work area orderly.

Contact Information

Soo-Hee Cho
Center for Medical Innovation (CMI), Room B2309

+82-2-2072-1871

21071-1@snuh.org