Analysis Items
This page lists the analysis services provided by the Immunology Laboratory—such as flow cytometry, CyTOF, and IMC—and the usage items for the NEPA, AMAXA, and GentleMACS equipment.
| No. | Analysis Item | Unit | Description |
|---|---|---|---|
| 1 | Single cell dissociation (Per sample) | sample | Flow cytometry sample preprocessing (analysis service or collaborative research) |
| 2 | Immune cell profiling (1 panel up to 9-color, 1 sample) | sample | Flow cytometry staining and data analysis (analysis service or collaborative research) |
| 3 | Single cell dissociation for CyTOF | sample | CyTOF sample preprocessing (analysis service or collaborative research) |
| 4 | Antibody staining for CyTOF (Human) (~30 Ab) | sample | Human CyTOF staining (analysis service or collaborative research) |
| 5 | Antibody staining for CyTOF (Mouse) (~30 Ab) | sample | Mouse CyTOF staining (analysis service or collaborative research) |
| 6 | CyTOF running | sample | Use of CyTOF equipment (analysis service or collaborative research) |
| 7 | CyTOF Data Analysis | sample | CyTOF data analysis (analysis service or collaborative research) |
| 8 | Antibody staining for IMC (Human) (~30 Ab) | sample | Human IMC staining (analysis service or collaborative research) |
| 9 | Antibody staining for IMC (Mouse) (~30 Ab) | sample | Mouse IMC staining (analysis service or collaborative research) |
| 10 | IMC running | ROI | Use of IMC equipment (analysis service or collaborative research) |
| 11 | IMC Data Analysis | ROI | IMC data analysis (analysis service or collaborative research) |
| 12 | Protein lysis for CBA (1 sample) | sample | Protein lysis for CBA (analysis service or collaborative research) |
| 13 | One-step qPCR (per 1 sample, 1 target) | sample | One-step qPCR (analysis service or collaborative research) |
| 14 | PBMC isolation (Up to 50mL) | sample | PBMC isolation (analysis service or collaborative research) |
| 15 | RNA probe tagging and staining | sample | RNA staining applicable to IMC (analysis service or collaborative research) |
| 16 | Sample subset setting (night) | 30 min | FACSsymphony A3 equipment usage fee |
| 17 | NEPA | 30 min | NEPA equipment usage fee (individual use) |
| 18 | AMAXA 4D | 30 min | AMAXA 4D equipment usage fee (individual use) |
| 19 | GentleMACS | 1 hour | GentleMACS equipment usage fee (individual use) |
| 20 | NEPA, AMAXA 4D, GentleMACS research technical support service | case | Equipment training |
| 21 | NEPA consumables (cuvettes) | 1 ea | NEPA cuvette cost |
| 22 | GentleMACS dedicated tube | 1 ea | C-tube / M-tube cost |
| 23 | GentleMACS Strainer | 1 ea | MACS SmartStrainer 70μm / 100μm cost |