FACSymphony S6

FACSymphony S6
FACSymphony S6 specifications
ModelFACSymphony S6
ManufacturerBD Biosciences
Year Introduced2022
Usage TypeAnalysis Request (paid)
Specifications5 Laser, 20 Detector
FeaturesA high-performance cell sorter that links high-dimensional flow cytometry with cell sorting. Precise isolation of immune cell subsets and rare cell populations based on multi-color panels. Supports a variety of collection formats such as tube, plate, and slide. Enables single-cell sorting and integration with downstream analysis.
Main ApplicationsMulticolor-based cell sorting, rare population sorting, immune cell subset sorting, single-cell multiomics preprocessing, tube/plate-based cell sorting
UsageResearchers requesting for the first time should contact the staff by email in advance (specify sample type, expected cell count, marker/fluorochrome used, expected gating strategy, and target population for sorting). Personal use not available.
LocationMedical Research Innovation Center (CMI), Room B2306

FACSAria II

FACSAria II
FACSAria II specifications
ModelFACSAria II
ManufacturerBD Biosciences
Year Introduced2009
Usage TypeAnalysis Request (paid)
Specifications3 Laser, 15 Detector
FeaturesA cell sorter for high-speed isolation of target cell populations based on multicolor analysis. Supports 2-way/4-way sorting and tube/plate/single-cell sorting. Suitable for cell line establishment, reporter-positive cell sorting, enrichment of specific cell populations, and obtaining cells for downstream culture or omics analysis.
Main Applications2-way/4-way sorting, single-cell sorting, plate sorting, sorting of cell lines, immune cells, and rare cells
UsageResearchers requesting for the first time should contact the staff by email in advance. Personal use not available.
LocationMedical Research Innovation Center (CMI), Room B2306

FACSymphony A5 SE

FACSymphony A5 SE
FACSymphony A5 SE specifications
ModelFACSymphony A5 SE
ManufacturerBD Biosciences
Year Introduced2024
Usage TypeAnalysis Request (paid) · Personal Use (paid)
Specifications5 Laser, 48 Detector
FeaturesA high-parameter cell analyzer that supports both spectral unmixing and conventional compensation workflows. Flexible configuration of complex fluorochrome combinations through 48-detector spectral analysis. The autofluorescence unmixing function improves analytical resolution even for samples with high autofluorescence.
Main ApplicationsHigh-dimensional analysis of 12 or more colors (spectral flow cytometry, complex immunophenotyping, analysis of autofluorescent samples, multicolor panel development, rare population analysis)
UsageRequests: contact the staff by email in advance. Personal use: email an inquiry specifying your equipment experience, analysis objectives, sample type, and so on.
LocationMedical Research Innovation Center (CMI), Room B2306

FACSymphony A3

FACSymphony A3
FACSymphony A3 specifications
ModelFACSymphony A3
ManufacturerBD Biosciences
Year Introduced2019
Usage TypeAnalysis Request (paid) · Personal Use (paid)
Specifications5 Laser, 20 Detector
FeaturesSuitable for high-dimensional flow cytometry based on conventional compensation. Its 5-laser, 20-color configuration allows the use of diverse fluorochrome combinations. Used for multicolor analysis such as immune cell subset analysis and intracellular cytokine staining.
Main Applications1~12 color analysis (high-dimensional immunophenotyping, T/NK/B cell subset analysis, intracellular cytokine staining, rare cell analysis, multicolor panel validation)
UsageFor both requests and personal use, contact the staff by email in advance.
LocationMedical Research Innovation Center (CMI), Room B2306

FACSLyric

FACSLyric
FACSLyric specifications
ModelFACSLyric
ManufacturerBD Biosciences
Year Introduced2020
Usage TypeAnalysis Request (paid) · Personal Use (paid)
Specifications3 Laser, 12 Detector (IVD equipment)
FeaturesA flow cytometer suited to standardized flow cytometry workflows. It analyzes up to 12 fluorochromes and improves the reproducibility and operational efficiency of routine assays through automated QC and a standardized acquisition/compensation workflow. Suitable for repeated analysis with standardized panels, 1–6 color analysis, and CBA analysis.
Main Applications1–6 color analysis, CBA analysis, routine multicolor analysis, standardized immunophenotyping, repeated-measurement assays
UsageFor both requests and personal use, contact the staff by email in advance.
LocationMedical Research Innovation Center (CMI), Room B2306

FACSCanto

FACSCanto
FACSCanto specifications
ModelFACSCanto
ManufacturerBD Biosciences
Year Introduced2014
Usage TypeAnalysis Request (paid) · Personal Use (paid)
Specifications3 Laser, 10 Detector (IVD)
FeaturesA basic analytical flow cytometer within the Flow Cytometry Laboratory. Suitable for low-parameter assays. Used for functional analyses such as cell cycle, apoptosis, ROS, and CFSE proliferation assays, as well as simple 1–2 color fluorescence analysis.
Main Applications1–2 color analysis, cell cycle and apoptosis analysis, ROS, CFSE, etc.
UsageFor both requests and personal use, contact the staff by email in advance.